Installation and
Maintenance
Manual for the
ASHCROFT
®
Type
1305D Deadweight
Tester and Type
1327D Portable
Pump
Installation and
Maintenance
Manual for the
ASHCROFT
®
Type
1305D Deadweight
Tester and Type
1327D Portable
Pump
I&M002-10095 4/02 (250-1526) Rev. 7/05
Vista de pagina 0
1 2 3 4 5 6 ... 19 20

Indice de contenidos

Pagina 1

Installation andMaintenanceManual for theASHCROFT®Type1305D DeadweightTester and Type1327D PortablePumpInstallation andMaintenanceManual for theASHCRO

Pagina 2

3.3.6 To Dismantle To replace the tester in its case, remove the gauge offsetpipe assembly (64 or 66) and the piston and cylinderassembly (67 or 79).

Pagina 3

towards the pump body and continue pumping to thedesired test pressure. Open the release valve (37) to ventthe pressure. To check operation pull the s

Pagina 4 - , with pipe adapters for

is affected somewhat by temperature, and by the elasticdistortion of the piston and cylinder when pressure isbeing applied. The effective area of a st

Pagina 5

d.Unscrew shuttle valve plug (43) and remove O-ring packing (27).e. Remove check valve spring (14) and check valve (44).f. Remove O-ring packing (15)

Pagina 6

Figure 2-2Ashcroft Portable Test Pump – Type 1327D

Pagina 7 - *Includes Test Pump Only

e. Slide check valve (44) and check valve spring (14)into body assembly (2).5.20 Replacing Reservoir and Fill Tubea.Replace plug (22).b. Replace fill

Pagina 8 - 4 inch (1.9

Pressure does not build up whenpumping handle.Insufficient fluidlevel in reservoir.Piston O-ringsworn or ruptured.Bleed port checkvalve or shuttlechec

Pagina 10 - 2 in (57 cm) depth

REPLACEMENT PARTS – D SERIES – BLUE COLORPORTABLE DEADWEIGHT TESTER – TYPE 1305DPORTABLE TEST PUMP – TYPE 1327DQty.Item PerNo. Asmy. Part No. Descript

Pagina 11

INDIVIDUAL WEIGHTSPartPressure RangeNumber Units Low HighLF199D psig 1 5LPF462 psig 2 10LAZ199D psig 5 25LAZ199 psig 10 50LAZ199A psig 20 100LAZ199B p

Pagina 13

All specifications are subject to change without notice. All sales subject to standard terms and conditions. ©Ashcroft Inc. I&M002-10095 4/02 (250

Pagina 14

1.0 PURPOSE AND SCOPE OF MANUALThis manual is provided to guide users of Model 1305Dand 1327D pressure testing devices in:(1) installing the equipment

Pagina 15 - Fax: (203) 385-0402

The deadweight tester consists of a two stage hydraulicpump containing a manifold which is pressurized duringoperation. Integral to the pump is a shut

Pagina 16

Model Piston Assembly Piston NetNumber Pressure Range Piston Area Value Number of Weights by Value WeightL-5 L-10 L-20 L-40 L-100psi Type Low High Low

Pagina 17

Pressure values produced by the pump are able to beclearly read to within ±0.25% accuracy of the span of theprecision test gauge selected for testing.

Pagina 18 - D SERIES – BLUE COLOR

Unit Of Model Tools & Net WeightMeasure Number Case Access. Gauge Range(s) Included lbs. kg1327*1327H* – – – – – – 12 51327O1327D1327DH X X – – –

Pagina 19 - INDIVIDUAL WEIGHTS

One Weight Box:10 inch (25 cm) width; 10 inch (25 cm); 10 inch (25 cm)heightStorage space dimensions are larger than actual size oftester carrying cas

Pagina 20

Figure 2-1Ashcroft Portable Deadweight Tester 1305D