P
ressing the
M
ODE key for 3 seconds displays “_ _ _. To return to measurement mode, the
_ _ _” display will flash when 3 seconds have passed.
MODE
425&7&9478*99.3,24)*
445(-*(024)*
• Compararator use/no use
• Hysteresisoperation setting
-Setting point, deadband setting
-
On, Off delay time setting
• Window comparator operation setting
-
Output settind range setting
Loop check mode
-Manually test display value, com-
p
arator output and analog output
without relation to impressed
p
ressure
• Read/storage of setting value
• Pressure display
• Comparator output
• Analog output
More than 3 sec
M
ODE
More than 3 sec
M
ODE
Less than 3 sec
MODE
More than 3 sec
*&8:7*2*3924)*
Power
MODE
More than 1 sec
• Zero point adjustment of
pressure display and analog
ouput
%*7454.39&)/:892*3924)*
• Comparator operation selection
-Hysteresis/window comparator
Select collector output type
-NPN ouput / PNP output
Filter (damping)selection
• Power-save setting
LED ring feature setting
• Display selection (scaling)
Analog output scaling selection
:3(9.438*99.3,24)*
• Peak hold display
Max. display value display
• Bottom hold display
Min. display value display
*&0'49942-41)).851&=24)*
• Key lock state
*=14(024)*
MODE
More than 1 sec
MODE
More than 3 sec
Finish
Finish
Finish
Hold or Key
Hold or Key
!  
*9:59*58
Pressing the
MODE key greater than 3 seconds will display Function Setting Mode. Scroll
through appropriate displays and select feature to change/confirm. LED ring will flash until
this menu is exited to the Measurement Mode by holding the
MODE key for more than 3
seconds. The setting mode is used to select comparator operation, pressure unit, indication
scaling, scaling of analog output and filter time constant.
Note: Editing the setting value in function setting mode recalculates all of the setting values includ-
ing the comparator. Please note that when the recalculated setting values are out of the display
range, they will be adjusted to the upper or lower limit value that can be processed internally.
Function Setting Notes
Comparator Operation Selection
For the unit equipped with two comparator output option, both comparators will be in the same
operation mode.
Filter Setting
The GC35 is equipped with 5 internal time constant filters. Use of the function is recommended
when measuring transient pressure source such that display, comparator output, analog output do
not stabilize. The selected time constant filter is reflected on comparator/analog output as well.