Quick Start Function Summary
Instructions for ASHCROFT
®
GC52 Differential Pressure
Transmitter
Version 6.03 Rev. B
(See Complete I&M Manual for Further Detail)
LOOK FOR THIS
AGENCY MARK ON
OUR PRODUCTS
© 2010 Ashcroft Inc., 250 East Main St., Stratford, CT 06614-5145, USA, Tel: 203-378-8281, Fax: 203-385-0499,
www.ashcroft.com All sales subject to standard terms and conditions of sale.
I&M011-10164-GC52 Ver. 6.03 Rev. B 03/11
Vista de pagina 0
1 2 3 4 5 6 ... 15 16

Indice de contenidos

Pagina 1 - Version 6.03 Rev. B

Quick Start Function SummaryInstructions for ASHCROFT®GC52 Differential PressureTransmitterVersion 6.03 Rev. B(See Complete I&M Manual for Further

Pagina 2

10uMuMuMuMuMN ROTd 0 d i d Z d 3a 100.0L 10.0P. 4.00a 0.0U SE1U SE( U houU n~In U 10 U 100 U 1000Flow Measurement Mode(Square

Pagina 3 - 8.8.8.8.8.8

114. WIRINGPower supply requirements, 12-36Vdc, note installation recommendations as follows:Terminal Strip: SMKDSP1.5/2-5.08 Phoenix contactA. Cable

Pagina 4

12DisplayWire terminalsWire Turn with a screwdriverLCD clips (4)Display boardPower supply terminal block• Remove cover and carefully remove the displ

Pagina 5

13100075050025000 322010102030Load Limitations 4-20mA Output Only12 24545OPERATINGREGIONLoop Resistance (V)LOOP SUPPLY VOLTAGEVmin= 12V+[.022A*RL)]*In

Pagina 8

16© 2010 Ashcroft Inc., 250 East Main St., Stratford, CT 06614-5145, USA, Tel: 203-378-8281, Fax: 203-385-0499,www.ashcroft.com All sales subject to s

Pagina 10 - 21 Flow Rate

3CH+CH–GC52In H2OM▼▲bDifferential pressureunit monitorTest TerminalsdMODE keyeDOWN keyfUP keycScaling - Arbitraryunit monitorh No functionaMeasured da

Pagina 11

411..UPON POWER-UP the unit enters “Measure Mode” – displaying applied pressure.22..TWO FUNCTION is available to the user in “Measure Mode”.A. Zero Ad

Pagina 12

53. To adjust Output Zero Point (4mA) and Output Span Point(20mA) the unit must be in the functional area as noted belowwhile adjustment is via $#keys

Pagina 13

6Setting LCD Setting SettingItem Display Description Rangen00l0nSelection of linear displaymode: Linnon: Differentialpressure displaymode; Lin: Linear

Pagina 14

7k = Dm00Pm100公In addition, the coefficient k is determined by substituting the maximummomentary flow rate Dm, which is measured from the formula (a)

Pagina 15

8• The indicated value which is blinking is integrated during the "blink"display at the time of momentary flow rate display span OVER.Flow M

Pagina 16

9uMuMuMuMuMuMuMuMuMuMuMuMuMuMuMuMabecdfghijklu 6.00f 2n nonn l na 10.0a 90.0[ 1.00[ 1.00p 20.0p 120.0d 1d 0.0d 50.0a 0.0a 100.0[ 5