Ashcroft GC51 - Industrial Rangeable Pressure Transmitter Manual de usuario Pagina 24

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 32
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 23
24
Setting LCD Setting Setting
No. Item Display Description Range Default*
Filter Selection of 1,2,4,8,
moving average 16 times 4
time of pressure
: 8 (times)
Setting LCD Setting Setting
No. Item Display Description Range Default*
Display Selection of non:pressure
mode pressure display display mode non
mode : non Lin: linear
display mode
Output Analog Pressure
zero point† output zero point range:–10 0.0
(4mA) : 10.0 (%F.S.) to 110%F.S.
Output Analog Pressure
span point† output span point range:–10 100.0
(20mA) : 90.0 (%F.S.) to 110%F.S.
Loop Arbitrary change of Display: Output
check‡ pressure display and zero point 0.0
analog output pressure to (4mA)
: 10 psi span point
pressure
Analog output
4 to 20mA
f 8
a 90.0
a 10.0
[010.0
n non
-
*The default is the factory default.
The following table is the setting. Example 1, Pressure Display Mode,
Section 11-2. This applies when re-scaling in psi” units.
Note: see page 24 for full menu.
†For setting of zero point and span point in the analog output, input the percent
value over the pressure range.
‡Regardless of applied pressure, the loop check can be activated, refer to
Section 13.4. This example shows the LCD display at the zero point at the start
of loop check start.
Vista de pagina 23
1 2 ... 19 20 21 22 23 24 25 26 27 28 29 30 31 32

Comentarios a estos manuales

Sin comentarios